<?xml version="1.0" encoding="UTF-8"?>

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="RejectionReasonsForLabOrderVS"/>
  <text>
    <status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet RejectionReasonsForLabOrderVS</b></p><a name="RejectionReasonsForLabOrderVS"> </a><a name="hcRejectionReasonsForLabOrderVS"> </a><a name="RejectionReasonsForLabOrderVS-en-US"> </a><ul><li>Include these codes as defined in <a href="CodeSystem-LabOrderRejectionReasonsCS.html"><code>http://fhir.nphl.go.ke/CodeSystem/LabOrderRejectionReasonsCS</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC1">KEID.RC1</a></td><td>EID-Rejection-RC1 - Unlabeled DBS</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC2">KEID.RC2</a></td><td>EID-Rejection-RC2 - Over saturation</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC3">KEID.RC3</a></td><td>EID-Rejection-RC3 - Insufficient blood</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC4">KEID.RC4</a></td><td>EID-Rejection-RC4 - Scratched spots</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC5">KEID.RC5</a></td><td>EID-Rejection-RC5 - Scattered spots</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC6">KEID.RC6</a></td><td>EID-Rejection-RC6 - Two layered spot</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC7">KEID.RC7</a></td><td>EID-Rejection-RC7 - Sample not due</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC8">KEID.RC8</a></td><td>EID-Rejection-RC8 - Samples packed together</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC9">KEID.RC9</a></td><td>EID-Rejection-RC9 - Clotted blood</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC10">KEID.RC10</a></td><td>EID-Rejection-RC10 - Improper drying</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC11">KEID.RC11</a></td><td>EID-Rejection-RC11 - Serum rings –water, alcohol</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC12">KEID.RC12</a></td><td>EID-Rejection-RC12 - Collected on expired DBS card</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC13">KEID.RC13</a></td><td>EID-Rejection-RC13 - Overstayed specimen ( &gt;2wks )</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC14">KEID.RC14</a></td><td>EID-Rejection-RC14 - Above 2years</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KEID.46RC15">KEID.RC15</a></td><td>EID-Rejection-RC15 - Sample &amp; requisition mismatch</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC1">KVL.RC1</a></td><td>VL-Rejection-RC1 - Missing Sample</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC2">KVL.RC2</a></td><td>VL-Rejection-RC2 - Hemolysed sample</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC3">KVL.RC3</a></td><td>VL-Rejection-RC3 - Missing patient</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC4">KVL.RC4</a></td><td>VL-Rejection-RC4 - Sample request form &amp; sample mismatch</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC5">KVL.RC5</a></td><td>VL-Rejection-RC5 - Sample not under cold chain</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC6">KVL.RC6</a></td><td>VL-Rejection-RC6 - Expired PPT tubes</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC7">KVL.RC7</a></td><td>VL-Rejection-RC7 - No request form</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC8">KVL.RC8</a></td><td>VL-Rejection-RC8 - Improper packaging</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KVL.46RC9">KVL.RC9</a></td><td>VL-Rejection-RC9 - Insufficient volume</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC1">KTB.RC1</a></td><td>TB-Rejection-RC1 - Leaking</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC2">KTB.RC2</a></td><td>TB-Rejection-RC2 - Request form without samples</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC3">KTB.RC3</a></td><td>TB-Rejection-RC3 - Mismatch Information on requset from and specimen container</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC4">KTB.RC4</a></td><td>TB-Rejection-RC4 - No label</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC5">KTB.RC5</a></td><td>TB-Rejection-RC5 - No sample in the container</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC6">KTB.RC6</a></td><td>TB-Rejection-RC6 - No requset form</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC7">KTB.RC7</a></td><td>TB-Rejection-RC7 - Missing information required</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC8">KTB.RC8</a></td><td>TB-Rejection-RC8 - Sample in the wrong container</td></tr><tr><td><a href="CodeSystem-LabOrderRejectionReasonsCS.html#LabOrderRejectionReasonsCS-KTB.46RC9">KTB.RC9</a></td><td>TB-Rejection-RC9 - Delay between sample collection and reception at NTRL</td></tr></table></li></ul></div>
  </text>
  <url value="http://fhir.nphl.go.ke/ValueSet/RejectionReasonsForLabOrderVS"/>
  <version value="0.1.0"/>
  <name value="RejectionReasonsForLabOrdersVS"/>
  <title value="ValueSet: Rejection reasons for Lab Orders"/>
  <status value="draft"/>
  <experimental value="false"/>
  <date value="2024-11-27T16:57:00+03:00"/>
  <publisher value="DNLS"/>
  <contact>
    <name value="DNLS"/>
    <telecom>
      <system value="url"/>
      <value value="http://nphl.go.ke"/>
    </telecom>
  </contact>
  <description value="Rejection reasons for lab orders in this IG"/>
  <compose>
    <include>
      <system value="http://fhir.nphl.go.ke/CodeSystem/LabOrderRejectionReasonsCS"/>
      <concept>
        <code value="KEID.RC1"/>
        <display value="EID-Rejection-RC1 - Unlabeled DBS"/>
      </concept>
      <concept>
        <code value="KEID.RC2"/>
        <display value="EID-Rejection-RC2 - Over saturation"/>
      </concept>
      <concept>
        <code value="KEID.RC3"/>
        <display value="EID-Rejection-RC3 - Insufficient blood"/>
      </concept>
      <concept>
        <code value="KEID.RC4"/>
        <display value="EID-Rejection-RC4 - Scratched spots"/>
      </concept>
      <concept>
        <code value="KEID.RC5"/>
        <display value="EID-Rejection-RC5 - Scattered spots"/>
      </concept>
      <concept>
        <code value="KEID.RC6"/>
        <display value="EID-Rejection-RC6 - Two layered spot"/>
      </concept>
      <concept>
        <code value="KEID.RC7"/>
        <display value="EID-Rejection-RC7 - Sample not due"/>
      </concept>
      <concept>
        <code value="KEID.RC8"/>
        <display value="EID-Rejection-RC8 - Samples packed together"/>
      </concept>
      <concept>
        <code value="KEID.RC9"/>
        <display value="EID-Rejection-RC9 - Clotted blood"/>
      </concept>
      <concept>
        <code value="KEID.RC10"/>
        <display value="EID-Rejection-RC10 - Improper drying"/>
      </concept>
      <concept>
        <code value="KEID.RC11"/>
        <display value="EID-Rejection-RC11 - Serum rings –water, alcohol"/>
      </concept>
      <concept>
        <code value="KEID.RC12"/>
        <display value="EID-Rejection-RC12 - Collected on expired DBS card"/>
      </concept>
      <concept>
        <code value="KEID.RC13"/>
        <display value="EID-Rejection-RC13 - Overstayed specimen ( &gt;2wks )"/>
      </concept>
      <concept>
        <code value="KEID.RC14"/>
        <display value="EID-Rejection-RC14 - Above 2years"/>
      </concept>
      <concept>
        <code value="KEID.RC15"/>
        <display value="EID-Rejection-RC15 - Sample &amp; requisition mismatch"/>
      </concept>
      <concept>
        <code value="KVL.RC1"/>
        <display value="VL-Rejection-RC1 - Missing Sample"/>
      </concept>
      <concept>
        <code value="KVL.RC2"/>
        <display value="VL-Rejection-RC2 - Hemolysed sample"/>
      </concept>
      <concept>
        <code value="KVL.RC3"/>
        <display value="VL-Rejection-RC3 - Missing patient"/>
      </concept>
      <concept>
        <code value="KVL.RC4"/>
        <display value="VL-Rejection-RC4 - Sample request form &amp; sample mismatch"/>
      </concept>
      <concept>
        <code value="KVL.RC5"/>
        <display value="VL-Rejection-RC5 - Sample not under cold chain"/>
      </concept>
      <concept>
        <code value="KVL.RC6"/>
        <display value="VL-Rejection-RC6 - Expired PPT tubes"/>
      </concept>
      <concept>
        <code value="KVL.RC7"/>
        <display value="VL-Rejection-RC7 - No request form"/>
      </concept>
      <concept>
        <code value="KVL.RC8"/>
        <display value="VL-Rejection-RC8 - Improper packaging"/>
      </concept>
      <concept>
        <code value="KVL.RC9"/>
        <display value="VL-Rejection-RC9 - Insufficient volume"/>
      </concept>
      <concept>
        <code value="KTB.RC1"/>
        <display value="TB-Rejection-RC1 - Leaking"/>
      </concept>
      <concept>
        <code value="KTB.RC2"/>
        <display value="TB-Rejection-RC2 - Request form without samples"/>
      </concept>
      <concept>
        <code value="KTB.RC3"/>
        <display value="TB-Rejection-RC3 - Mismatch Information on requset from and specimen container"/>
      </concept>
      <concept>
        <code value="KTB.RC4"/>
        <display value="TB-Rejection-RC4 - No label"/>
      </concept>
      <concept>
        <code value="KTB.RC5"/>
        <display value="TB-Rejection-RC5 - No sample in the container"/>
      </concept>
      <concept>
        <code value="KTB.RC6"/>
        <display value="TB-Rejection-RC6 - No requset form"/>
      </concept>
      <concept>
        <code value="KTB.RC7"/>
        <display value="TB-Rejection-RC7 - Missing information required"/>
      </concept>
      <concept>
        <code value="KTB.RC8"/>
        <display value="TB-Rejection-RC8 - Sample in the wrong container"/>
      </concept>
      <concept>
        <code value="KTB.RC9"/>
        <display value="TB-Rejection-RC9 - Delay between sample collection and reception at NTRL"/>
      </concept>
    </include>
  </compose>
</ValueSet>